High Performance
? Low Distortion Interference, Complete Input/Output Isolation
? The maximum single-phase capacity can reach 15KVA and the three-phase power supply can reach 45KVA.
? Remote voltage feedback function to ensure the consistency of test point voltage value and setting value
? Voltage and current measurements are based on high precision ADC AC sampling and digital real value calculation.
? A single chip computer (D/A circuit) is used to collect voltage and current waveform data directly.
? contains RS232 or RS485 interface, communicate with computer. Five groups of test groups can be set up on a single machine. Each group can set up 35 different test points (different voltage0~300V, frequency45~500Hz, time 0.1S~999.9H and can do (0~999999) cycle test.
? Built-in soft start device can easily start motor, compressor and other high starting current load
? The central processing unit is used to control the opening and closing of logic circuits.
? In-machine temperature and humidity detection, intelligent exhaust dehumidification, ensure the normal use of power supply
Humanized design
? Ultra-large 7-inch touch screen displays parameters: voltage, frequency, power, power factor, current, peak current, temperature, electric quantity, time, phase angle, impedance value and real-time curve of voltage and current.
? Power supply multi-point real-time sensor monitoring, running normal code and fault code screen display, fully control the power supply status.
? The parameter calibration is accomplished by open software, and different from other power sources, the potentiometer and adjustable resistance are also adjusted in the circuit.
? Wide range of voltage and frequency regulation, digital key input, independent display of three-phase voltage and line voltage
? Digital password lock, test data security and prevent important test data from being modified by misoperation
APA2000L Single phase series
Model | 2000L | 2001L | 2002L | 2003L | 2005L | 2010L | 2015L |
---|---|---|---|---|---|---|---|
Output Capacity | 500VA | 1KVA | 2KVA | 3KVA | 5KVA | 10KVA | 15KVA |
Input Power | 1?2W+G 110V/220V±10% 50/60Hz±5% | ||||||
Output Frequency | 50Hz/ 60Hz/ 45~500Hz | ||||||
Frequency stability | 0.01% | ||||||
Output Voltage | 0~150V/0~300V(AUTO) | ||||||
Output current | 4.2/2.1 | 8.4/4.2 | 16.8/8.4 | 25/12.5 | 42/21 | 84/42 | 126/63 |
Load Regulation | ≤0.5% | ||||||
Waveform Distortion | ≤0.3% | ||||||
Meter Display | Touch screen display Voltage, frequency, power, power factor, current, peak current, temperature, electric quantity, time, phase angle,Impedance value and Real-time Curve of Voltage and Current | ||||||
Protective Device | Overload, Overcurrent, Temperature, Short Circuit, Undervoltage Protection and Alarm | ||||||
Working condition | ambient temperature 0~40°C relative humidity10~90% |
APA2000LS Three phase series
Model | 2006LS | 2010LS | 2015LS | 2020LS | 2030LS | 2045LS |
---|---|---|---|---|---|---|
Output Capacity | 6KVA | 10KVA | 15KVA | 20KVA | 30KVA | 45KVA |
Input Power | 1?2W+G 220V±10% | 3?4W+G 220V/380V±10% 50/60Hz±5% | ||||
Output Frequency | 50Hz/ 60Hz/ 45~500Hz | |||||
Frequency stability | 0.01% | |||||
Output Voltage | 0~150V/0~300V(AUTO) | |||||
Output current | 16.8/8.4 | 27.5/13.75 | 42/21 | 55.6/27.8 | 84/42 | 126/63 |
Load Regulation | ≤0.5% | |||||
Waveform Distortion | ≤0.3% | |||||
Meter Display | Touch screen display Voltage, frequency, power, power factor, current, peak current, temperature, electric quantity, time, phase angle,Impedance value and Real-time Curve of Voltage and Current | |||||
Protective Device | Protection and alarm of short circuit, short voltage and short phase with overload, over current and over temperatur | |||||
Working condition | ambient temperature 0~40°C relative humidity10~90% |